x-fresh® air conditioning units Light Commercial Split System
High performance, versatile designs
Customised solutions for every room size. Cooling without compromise - at any time.
Highlights
Models
Documents
- High output of up to 16 kW - ideal for offices, shops and catering establishments with larger cooling or heating requirements
- Wide range of designs - cassette units, duct units or wall-mounted units for every room solution
- Efficient air conditioning of large areas thanks to even temperature distribution and low operating costs
- Twin connection for up to two indoor units for even air manifold in rooms with a large area or specific room geometry
For better air manifold in the room
x-fresh Light Commercial Split System - Twin
More power. More comfort. More efficiency.
With the twin configuration of the x-fresh Light Commercial Split System, rooms with a large area or complex geometry can be optimally air-conditioned.
Two indoor units, controlled synchronously via an outdoor unit, ensure an even air manifold - whether in two separate rooms or a spacious room concept.
The result: a pleasant indoor climate with minimal energy and installation costs.
The advantages:
- Efficient air conditioning of large or shared rooms
- Low installation costs due to only one outdoor unit
- Low operating costs and high energy efficiency
- Comfortable, even air manifold
Suitable for twin operation:
- x-fresh indoor cassette L
- x-fresh indoor duct
- x-fresh indoor ceiling / floor
The twin adapter is available as an option.
Combinations
Combination 35
- Indoor unit: x-fresh indoor cassette S 35C
Outdoor unit: x-fresh outdoor commercial S 35C - Power supply: 1 output 230V
- Cooling output (kW): 3.52
- Cooling output Btu/H: 12000
- SEER: 6.80
- Heating capacity (kW): 3.81
- Heating capacity Btu/H: 13000
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combination 53
- Indoor unit: x-fresh indoor cassette S 53C
Outdoor unit: x-fresh outdoor commercial S 53C - Power supply: 1 output 230V
- Cooling output (kW): 5.28
- Cooling output Btu/H: 18000
- SEER: 6.50
- Heating capacity (kW): 5.33
- Heating capacity Btu/H: 18000
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combinations
Combination 70
- Indoor unit: x-fresh indoor cassette L70C
Outdoor unit: x-fresh outdoor commercial S 70C - Power supply: 1 output 230V
- Cooling output (kW): 7.03
- Cooling output Btu/H: 24000
- SEER: 6.10
- Heating capacity (kW): 7.62
- Heating capacity Btu/H: 26000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 80
- Indoor unit: x-fresh indoor cassette L88C
Outdoor unit: x-fresh outdoor commercial S 88C - Power supply: 1 output 230V
- Cooling output (kW): 8.79
- Cooling output Btu/H: 30000
- SEER: 6.10
- Heating capacity (kW): 9.38
- Heating capacity Btu/H: 32000
- SCOP: 4.60
- Energy class cooling/heating: A++ / A+
Combination 105
- Indoor unit: x-fresh indoor cassette L105C
Outdoor unit: x-fresh outdoor commercial S 105C - Power supply: 1 output 230V
- Cooling output (kW): 10.6
- Cooling output Btu/H: 36000
- SEER: 6.10
- Heating capacity (kW): 11.1
- Heating capacity Btu/H: 38000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 120
- Indoor unit: x-fresh indoor cassette L120C
Outdoor unit: x-fresh outdoor commercial S 120C - Power supply: 1 output 230V
- Cooling output (kW): 12.0
- Cooling output Btu/H: 41000
- SEER: 6.10
- Heating capacity (kW): 13.5
- Heating capacity Btu/H: 46000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 140T
- Indoor unit: x-fresh indoor cassette L140C
Outdoor unit: x-fresh outdoor commercial S 140-TC - Power supply: 1 output 400V, 3+n phases
- Cooling output (kW): 14.1
- Cooling output Btu/H: 48000
- SEER: 6.10
- Heating capacity (kW): 16.1
- Heating capacity Btu/H: 55000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 160T
- Indoor unit: x-fresh indoor cassette L160C
Outdoor unit: x-fresh outdoor commercial S 160 TC - Power supply: 1 output 400V, 3+n phases
- Cooling output (kW): 15.2
- Cooling output Btu/H: 52000
- SEER: 6.10
- Heating capacity (kW): 18.2
- Heating capacity Btu/H: 62000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combinations
Combination 35
- Indoor unit: x-fresh indoor duct 35RC
Outdoor unit: x-fresh outdoor commercial S 35C - Power supply: 1 output 230V
- Cooling output (kW): 3.52
- Cooling output Btu/H: 12000
- SEER: 6.50
- Heating capacity (kW): 3.37
- Heating capacity Btu/H: 11500
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combination 53
- Indoor unit: x-fresh indoor duct 53RC
Outdoor unit: x-fresh outdoor commercial S 53C - Power supply: 1 output 230V
- Cooling output (kW): 5.28
- Cooling output Btu/H: 18000
- SEER: 6.50
- Heating capacity (kW): 6.00
- Heating capacity Btu/H: 20500
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combination 88
- Indoor unit: x-fresh indoor duct 88C
Outdoor unit: x-fresh outdoor commercial S 88C - Power supply: 1 output 230V
- Cooling output (kW): 8.00
- Cooling output Btu/H: 27300
- SEER: 6.60
- Heating capacity (kW): 9.38
- Heating capacity Btu/H: 32000
- SCOP: 4.20
- Energy class cooling/heating: A++ / A+
Combination 105
- Indoor unit: x-fresh indoor duct 105RC
Outdoor unit: x-fresh outdoor commercial S 105C - Power supply: 1 output 230V
- Cooling output (kW): 9.86
- Cooling output Btu/H: 36640
- SEER: 6.30
- Heating capacity (kW): 10.3
- Heating capacity Btu/H: 35000
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combination 120
- Indoor unit: x-fresh indoor duct 120RC
Outdoor unit: x-fresh outdoor commercial S 120C - Power supply: 1 output 230V
- Cooling output (kW): 11.0
- Cooling output Btu/H: 37500
- SEER: 6.10
- Heating capacity (kW): 13.5
- Heating capacity Btu/H: 46000
- SCOP: 4.10
- Energy class cooling/heating: A++ / A+
Combination 140T
- Indoor unit: x-fresh indoor duct 140RC
Outdoor unit: x-fresh outdoor commercial S 140-TC - Power supply: 1 output 400V, 3+n phases
- Cooling output (kW): 12.2
- Cooling output Btu/H: 41630
- SEER: 6.10
- Heating capacity (kW): 15.2
- Heating capacity Btu/H: 52000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combinations
Combination 35
- Indoor unit: x-fresh indoor case wall 35RC
Outdoor unit: x-fresh outdoor commercial S 35C - Power supply: 1 output 230V
- Cooling output (kW): 3.52
- Cooling output Btu/H: 12000
- SEER: 7.30
- Heating capacity (kW): 3.81
- Heating capacity Btu/H: 13000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 53
- Indoor unit: x-fresh indoor case wall 53RC
Outdoor unit: x-fresh outdoor commercial S 53C - Power supply: 1 output 230V
- Cooling output (kW): 4.98
- Cooling output Btu/H: 17000
- SEER: 6.70
- Heating capacity (kW): 5.28
- Heating capacity Btu/H: 18000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combinations
Combination 53
- Indoor unit: x-fresh commercial indoor ceiling/floor 53RC
Outdoor unit: x-fresh outdoor commercial S 53C - Power supply: 1 output 230V
- Cooling output (kW): 5.28
- Cooling output Btu/H: 18000
- SEER: 6.10
- Heating capacity (kW): 5.57
- Heating capacity Btu/H: 19000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 70
- Indoor unit: x-fresh commercial indoor ceiling/floor 70C
Outdoor unit: x-fresh outdoor commercial S 70C - Power supply: 1 output 230V
- Cooling output (kW): 7.03
- Cooling output Btu/H: 24000
- SEER: 6.10
- Heating capacity (kW): 7.62
- Heating capacity Btu/H: 26000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 105
- Indoor unit: x-fresh commercial indoor ceiling/floor 105C
Outdoor unit: x-fresh outdoor commercial S 105C - Power supply: 1 output 230V
- Cooling output (kW): 10.6
- Cooling output Btu/H: 36000
- SEER: 6.10
- Heating capacity (kW): 11.7
- Heating capacity Btu/H: 40000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 140T
- Indoor unit: x-fresh commercial indoor ceiling/floor 140C
Outdoor unit: x-fresh outdoor commercial S 140 TC - Power supply: 1 output 400V, 3+n phases
- Cooling output (kW): 14.1
- Cooling output Btu/H: 48000
- SEER: 6.10
- Heating capacity (kW): 16.10
- Heating capacity Btu/H: 55000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Combination 160T
- Indoor unit: x-fresh commercial indoor ceiling/floor 160C
Outdoor unit: x-fresh outdoor commercial S 160 TC - Power supply: 1 output 400V, 3+n phases
- Cooling output (kW): 15.8
- Cooling output Btu/H: 54000
- SEER: 6.10
- Heating capacity (kW): 18.2
- Heating capacity Btu/H: 62000
- SCOP: 4.00
- Energy class cooling/heating: A++ / A+
Documents and downloads