x-net® controls

Clever panel heating and surface cooling control.

The desired level of thermal comfort can be set individually for each room.

What’s more, clever control also means: savings. x-net controls are available in two product lines to cater for specific requirements.

Highlights
Models/system components
Documents & service

This is how the smart control works:

The room thermostats and the switch actuator are connected to one another via your home network. The x-net underfloor heating/cooling can be controlled at any time via the user screen using a tablet, smartphone, laptop, or PC – whether from work, while driving back from holiday, or on the sofa.

Operating principle of the x-net controls

The room control units – which are available with or without a display and in wired or wireless variants – are installed on the wall in the respective room.

Switch actuator (top image) and actuators (bottom image): upgradeable via micro-SD card for a future-proof solution. Multi-storey solutions via wireless technology or bus cable, ideal for a building with central management.

Operating principle of the x-net controls

Installation position: The switch actuator and actuators are installed in the x-net underfloor heating/cooling manifold cabinet.
The components are perfectly coordinated and ensure fast and secure installation as well as reliable operation.

Standard control

With the standard x-net control, the panel heating/surface cooling can be controlled really easily for each individual room in line with demand. The room controllers are available with or without a display, and also as a flush-mounted variant. Wired with electrical installation cable 5 x 1.5 mm².

Wall mounted controller LCD 230 V

  • Electronic PI controller with pulse width modulation
  • High-quality display showing actual temperature and operating state
  • Automatic mode and operation lock
  • Antifreeze protection and valve protection functions
  • Easy, language-neutral operation
  • Eco-operation/night-time reduction using input for external timer
  • Up to 4 actuators can be connected (230 V LCD wall-mounted controller)
  • Optional: T LCD wall-mounted controller
    With LC display + timer, max. 5 actuators with max. 3 watts/actuator
x-net standard control – 230 V LCD wall-mounted controller.

230 V wall-mounted controller

  • Bimetal 2-point controller with rotary knob
  • With thermal feedback
  • Up to 4 actuators can be connected
x-net standard control – 230 V wall-mounted controller.

230 V wall-mounted controller

  • Room temperature controller for heating and with rotary knob
  • Switching capacity: maximum 4 actuators
x-net standard control – 230 V wall-mounted controller.

230 V flush-mounted controller

  • Bimetal 2-point controller with rotary knob
  • With thermal feedback
  • Up to 4 actuators can be connected
  • For installation in flush-mounted boxes
x-net standard control – 230 V flush-mounted controller.

230 V dew point monitor

  • For early detection of the risk of condensation
  • If the temperature falls below the dew point, all affected actuators are closed
x-net standard control – 230 V dew point monitor.

Terminal strip plus

  • Connection unit for connecting the room temperature controller of the x-net standard control to the x-net actuators and EGO variable speed drives.
  • Quick, secure, and flexible installation in the manifold cabinet using the pre-assembled x-net quick fix set for magnetic surfaces.
  • Strain relief and overload protection integrated
  • For a maximum of 6 x-net room temperature controllers
  • Optional: terminal strip plus – with pump switch-off
x-net standard control – terminal strip plus.

Terminal strip flex plus

  • Connection unit for connecting the room temperature controller of the x-net standard control to the x-net actuators and EGO variable speed drives.
  • With rotary switches for variable assignment of all variable speed drives/actuators to the room temperature controllers. Quick, safe, and flexible installation in the manifold cabinet using the pre-assembled Kermi x-net quick fix set for magnetic surfaces.
  • 8 room temperature controllers and 12 variable speed drives/actuators can be connected
x-net standard control – terminal strip flex plus.

Control strip pro plus

  • Connection and control unit for connecting the room temperature controller from the x-net standard control to the x-net actuators. With integrated, automatic hydraulic balancing. The intelligent control characteristic ensures that the connected actuators are controlled in line with demand. TÜV certified, qualifies for the BEG subsidy for efficient buildings, meets the requirements of the German Buildings Energy Act (GEG). Heating and cooling functions provided via commercially available 230 V heating room controllers by inverting the controller signal in cooling mode. Quick, secure, and flexible installation in the manifold cabinet using the pre-assembled x-net quick fix set for magnetic surfaces.
  • Up to 8 room temperature controllers and 17 actuators can be connected
x-net standard control – control strip pro plus.

x-net ready line

Everything sorted with a single click. Thex-net ready line plus and x-net ready line EGO pluscontrol units create space for cable entry, save valuable time on the construction site, and – because they are already wired to the terminal strip – can be installed with a single click.

With x-net ready line EGO plus, hydraulic balancing is completed in a flash as well. Normally closed with a folding lever for unscrewing the thermostatic valve with ease or opening it manually without current. With an integrated flow temperature limiter. A room temperature controller from the x-net standard control is required for the variable speed drive to work.

x-net ready line plus

Fully wired Kermi flex plus terminal strip with Kermi 230 V x-net actuators and Kermi x-net quick fix set for quick installation in the x-net manifold cabinets. The actuators are wired in the terminal strip in accordance with VDE requirements, coded to prevent mix-ups, and secured with strain relief. The LED function indicator on the terminal strip and the function and control indicators on the actuators allow you to check – quickly and safely – whether they are working properly.

Consisting of:

  • Kermi 230 V flex plus 8R PU terminal strip
  • Kermi 230 V x-net actuators
  • Kermi x-net quick fix set
x-net home station control – x-net ready line.

x-net ready line EGO plus

Fully wired Kermi flex plus terminal strip with Kermi 230 V x-net EGO variable speed drives and Kermi x-net quick fix set for quick installation in the x-net manifold cabinets. The variable speed drives are wired in the terminal strip in accordance with VDE requirements, coded to prevent mix-ups, and secured with strain relief. The LED function indicator on the terminal strip and the LED function and control indicators on the variable speed drives allow you to check – quickly and safely – whether they are working properly.

Consisting of:

  • Kermi 230 V flex plus 8R PU terminal strip
  • Kermi 230 V x-net EGO variable speed drives
  • Kermi x-net quick fix set
x-net home station control – x-net ready line EGO.

x-net comfort control

Heating and cooling

The Kermi x-net comfort control for heating/cooling provides the highest level of operating comfort and control quality with energy savings of up to 20 %.
It’s so easy to make the settings you want – whether directly on the wall-mounted room thermostat at home or while out and about using a tablet or smartphone connected to the Internet. The x-net comfort control is completely future-proof because it has all the features required for heating and/or cooling systems, whether you opt for the wireless or the wired variant (2-wire bus protected against polarity reversal).

Room control unit with display
Wireless/wired

  • High-quality display showing actual temperature, operating state, and time
  • Automatic mode and operation lock
  • Antifreeze protection and valve protection functions
  • Easy, language-neutral operation
  • Comfort functions: holiday, party, presence, absence
  • Weekly program
  • Backlighting (wired)
  • Optional: with additional external sensor for detecting floor or room temperature

Room control unit without display
Wireless/wired

  • Setpoint limitation
  • Optional: public building model without control option

Switch actuator
Wireless/wired

  • Electronic PI controller with pulse width modulation
  • Load balancing through staggered activation of the actuators
  • Intelligent control with automatic adaptation to room properties
  • Up to 12 (cable connected) or 18 (radio) actuators can be connected
  • Up to 7 switch actuators can be connected (master-slave)
  • Pump shutdown
  • Heating and cooling with dew point monitor
  • Safety temperature limit with on-site safety temperature limiter
  • Freely programmable output (e.g. boiler shutdown)
Operating principle of the x-net controls

x-net +e control

Only for x-net +e11 mat system

Flush-mounted room temperature controller featuring LCD display with a floor temperature sensor and a protective conduit for the floor sensor with Metallic end cap.

  • Installation in flush-mounted boxes
  • Functions: daily and weekly program for individual heating periods with start optimisation according to eco-design directive (ErP 2015/1188)
  • Maximum or minimum floor temperature limit
  • Load disruption according to DIN EN 50559

Documents

Pricelist
Brochures
Datasheet
Instruction
Technical information
Declaration of performance

Images

We are proud to present our latest images, which you can view here.

Videos

All Kermi product and installation videos are also available for you to watch on YouTube whenever you like.

Customer service

Quotation and planning service for x-net panel heating and surface cooling

Are you looking for a Kermi specialist partner near you?

With our search, you can find a specialist partner near you that can assist you with consultation plus exhibition, with planning or with consultation and installation.